HVLS fans for manufacturing plants

For injection moulding, metal fabrication, automotive parts, printing and packaging, and woodworking.

What it does on a production floor

A manufacturing floor has its own heat problem. Machines, ovens, presses and moulding barrels put heat into the room all day, and in summer it pools around the people running them. In winter the opposite happens: the heaters warm the roof while the floor stays cold.

A GALE Series HVLS fan moves a large column of air slowly across the whole floor. In summer that means steady airflow around every station. In winter it pushes the warm air back down from the roof.

Summer

Moving air makes the space feel cooler for the people working in it. GALE Series fans create a cooling effect of up to 8°C in warm conditions, and that airflow reaches the middle of the floor, not only the stations near a wall fan.

Winter

Warm air rises to the roof, and the heaters keep running to warm the floor. A fan running at low speed mixes that air back down, so the floor holds temperature with less heating.

What that means for energy costs: 25 to 49% lower cooling costs and 20 to 30% lower heating costs. Each fan draws between 0.5 and 1.8 kW.

By type of plant

Plastics and injection moulding

Barrel heaters, hot runners and cooling parts make moulding floors some of the warmest in any plant. We place fans over the operator aisles, so the air moves around the people running the machines.

Metal fabrication and welding

Strong drafts can disturb shielding gas on MIG and TIG welds. We don't hang fans directly over welding bays. We place them so the air slows down before it reaches the welders, and set the fan speed on the drive, so the shop gets airflow without affecting weld quality.

Automotive parts and assembly

Long lines and large footprints. A few 24 ft fans cover ground that would take dozens of pedestal fans, without cords or fans in the walkways.

Printing and packaging

Steady, even airflow across the floor, without the gusts of high-speed fans.

Woodworking and millwork

We set speed and placement so the fans work with your dust collection rather than stirring dust back up.

Planning around the plant

Manufacturing buildings have more in the way than warehouses. We plan each layout around:

  • Overhead cranes, so fans sit clear of the crane path and the runway
  • Heat sources, so airflow reaches the people working near them
  • Welding bays, so fans sit away from them and the air slows before it reaches the welders
  • Ceiling height and roof structure, which set the fan size and mounting
  • Exhaust hoods and fume extraction, so fans don't blow across them and pull fumes away from the extraction
  • Shift patterns, so fans run when the floor is occupied

GALE Series models for manufacturing

GALE Series models for manufacturing plants, with coverage per fan, mounting height range and power draw
ModelDiameterCoverage per fanMounting heightPower
G-7.3E24 ftUp to 21,500 sq ft23–66 ft1.8 kW
G-7.3S24 ftUp to 16,100 sq ft23–59 ft1.5 kW
G-6.120 ftUp to 8,600 sq ft20–43 ft1.0 kW
G-5.518 ftUp to 6,400 sq ft16–36 ft0.9 kW
G-5.016 ftUp to 5,300 sq ft16–33 ft0.75 kW

Direct drive PMSM motors with no gearbox, so there's no oil to change. 38 dB or less, quieter than a normal conversation, so they don't add to the noise on the floor.

The Enbridge incentive and manufacturing plants

Enbridge Gas pays $3,000 to $4,000 per fan for destratification fans in qualifying Ontario buildings. The program is written for warehouse-type buildings, and many manufacturing plants meet the same requirements:

  • Ceilings at least 22 ft high
  • Heated by ceiling-mounted natural gas forced-air heaters, including unit heaters
  • Thermostat at floor level, with the heating at roof level
  • Kept at around 69°F on average

Two things commonly rule a plant out: radiant heaters in the area the fans would cover, and night setbacks, where the heat is turned down when the plant is closed. If you run around the clock, setbacks usually aren't an issue.

We check your building before you get a proposal. See the full requirements

Installation

In Ontario

We work with local electricians and schedule installation around your production, including evenings and shutdowns.

Outside Ontario

We find and qualify local installers in your area and supervise the installation. The installer's cost is quoted to you as-is.

How installation works

Frequently asked questions

Yes, with the right placement and speed. Strong drafts can disturb shielding gas on MIG and TIG welds, so we don't hang fans directly over welding bays. We place them so the air slows down before it reaches the welders, and set the fan speed on the drive.